Das Bild kann eine Darstellung sein.
Siehe Spezifikationen für Produktdetails.
P51-1500-A-T-P-20MA-000-000

P51-1500-A-T-P-20MA-000-000

Introduction

The P51-1500-A-T-P-20MA-000-000 is a precision pressure transducer designed for use in various industrial and commercial applications. This entry provides an overview of the product, including its category, use, characteristics, packaging, specifications, pin configuration, functional features, advantages and disadvantages, working principles, application field plans, and alternative models.

Basic Information Overview

  • Category: Precision Pressure Transducer
  • Use: Measurement and monitoring of pressure in industrial and commercial systems
  • Characteristics: High accuracy, reliability, and compatibility with diverse pressure ranges
  • Package: Compact and durable housing
  • Essence: Accurate pressure sensing and transmission
  • Packaging/Quantity: Typically sold individually or in small quantities

Specifications

  • Pressure Range: 0-1500 psi
  • Output: 4-20 mA
  • Accuracy: ±0.5% full scale
  • Operating Temperature: -40°C to 85°C
  • Supply Voltage: 10-28 VDC
  • Electrical Connection: Integral cable or connector options

Detailed Pin Configuration

The P51-1500-A-T-P-20MA-000-000 features a standard pin configuration with connections for power supply, signal output, and ground. The detailed pinout is as follows: 1. Power Supply (+) 2. Signal Output 3. Ground (-)

Functional Features

  • High Accuracy: Provides precise pressure measurements
  • Robust Construction: Suitable for harsh industrial environments
  • Wide Compatibility: Supports various pressure ranges and system configurations
  • Low Power Consumption: Efficient energy utilization

Advantages and Disadvantages

Advantages

  • High accuracy and reliability
  • Wide operating temperature range
  • Compact and durable design
  • Low power consumption

Disadvantages

  • Limited pressure range compared to some alternatives
  • Higher initial cost compared to standard pressure sensors

Working Principles

The P51-1500-A-T-P-20MA-000-000 operates on the principle of piezoresistive sensing. When subjected to pressure, the transducer's internal diaphragm deforms, causing a change in resistance in the sensing element. This change is then converted into a proportional electrical signal (4-20 mA) for pressure measurement and monitoring.

Detailed Application Field Plans

The P51-1500-A-T-P-20MA-000-000 is suitable for a wide range of applications, including: - Hydraulic systems - Industrial machinery - Process control - HVAC systems - Aerospace and automotive testing

Detailed and Complete Alternative Models

  • P51-1000-A-T-P-20MA-000-000: Lower pressure range variant
  • P51-2000-A-T-P-20MA-000-000: Higher pressure range variant
  • P51-1500-A-T-V-20MA-000-000: Variant with voltage output

In conclusion, the P51-1500-A-T-P-20MA-000-000 offers high accuracy and reliability in pressure measurement applications, making it a valuable component in various industrial and commercial systems.

Word Count: 411

Listen Sie 10 häufige Fragen und Antworten im Zusammenhang mit der Anwendung von P51-1500-A-T-P-20MA-000-000 in technischen Lösungen auf

  1. What is the P51-1500-A-T-P-20MA-000-000 sensor used for?

    • The P51-1500-A-T-P-20MA-000-000 sensor is a pressure transducer commonly used to measure and transmit pressure readings in various technical applications.
  2. What is the operating range of the P51-1500-A-T-P-20MA-000-000 sensor?

    • The operating range of the P51-1500-A-T-P-20MA-000-000 sensor typically covers pressures from 0 to 1500 psi.
  3. What type of output signal does the P51-1500-A-T-P-20MA-000-000 sensor provide?

    • The P51-1500-A-T-P-20MA-000-000 sensor provides a 4-20mA output signal, which is commonly used for transmitting sensor data over long distances.
  4. Can the P51-1500-A-T-P-20MA-000-000 sensor be used in high-temperature environments?

    • Yes, the P51-1500-A-T-P-20MA-000-000 sensor is designed to operate in high-temperature environments, making it suitable for a wide range of industrial applications.
  5. What are the typical applications for the P51-1500-A-T-P-20MA-000-000 sensor?

    • The P51-1500-A-T-P-20MA-000-000 sensor is commonly used in hydraulic systems, industrial machinery, process control, and automotive applications.
  6. Is the P51-1500-A-T-P-20MA-000-000 sensor suitable for use in corrosive environments?

    • Yes, the P51-1500-A-T-P-20MA-000-000 sensor is available with various materials and seals to make it compatible with corrosive media.
  7. What is the accuracy of the P51-1500-A-T-P-20MA-000-000 sensor?

    • The P51-1500-A-T-P-20MA-000-000 sensor typically offers high accuracy, often within ±0.25% of full scale.
  8. Can the P51-1500-A-T-P-20MA-000-000 sensor be integrated with digital control systems?

    • Yes, the P51-1500-A-T-P-20MA-000-000 sensor can be integrated with digital control systems using appropriate signal conditioning and interface modules.
  9. Does the P51-1500-A-T-P-20MA-000-000 sensor require calibration?

    • Yes, like most sensors, the P51-1500-A-T-P-20MA-000-000 sensor should be calibrated periodically to ensure accurate and reliable performance.
  10. What are the environmental ratings for the P51-1500-A-T-P-20MA-000-000 sensor?

    • The P51-1500-A-T-P-20MA-000-000 sensor typically has environmental ratings that make it suitable for use in harsh conditions, including water and dust resistance.